Used field erected/un-erected - condensing & non-condensing steam turbines for sale : 50 Hz Steam Turbines for Sale :
Steam turbine of 1 x 30 MW rated condensing TG Set, Pressure : 79 , 510 Deg.c
Steam turbine of 1 x 32 MW rated condensing-extraction TG Set, Pressure : 89 - 104 bar,
extraction : 4.5 bar, 520 Deg.c
Steam turbine of 1 x 27 MW rated condensing TG Set, Pressure : 90 bar, 530 Deg.c
Steam turbine of 1 x 20 MW rated Backpressure TG set, Pressure : 57 / 76 bar, 470/490 Deg.c
Steam turbine of 1x 10 MW rated condensing TG set, Pressure : 40 bar, 500 Deg.c
Steam turbine of 2 x 17 MW rated codensing TG set, Pressure : 40 bar, 465 Deg.c
Steam turbine of 1 x 11.7 MW rated condensing TG set, Pressure : 55 bar, 512 Deg.c
Steam turbine of 1 x 2.5 MW rated Backpressure TG set, pressure : 60 bar A, 480 Deg.c
New Steam turbine of 1 x 4 MW rated Backpressure TG Set, Pressure : 40/50 bar, Controlled extraction : 18 bar, Backpressure : 9 bar, 440/450 deg.c
Steam turbine of 1 x 1.5 MW rated backpressure TG set, pressure : 21 kg/cm2, 350 Deg.c, Model:550 mm
Steam turbine of 1 x 3 MW rated backpressure TG set, pressure : 33 kg/cm2, 460 Deg.c
Steam turbine of 1 x 5.2 MW rated backpressure TG set, pressure : 49 bar, 450 Deg.c
Steam turbine of 1 x 2.5 MW rated condensing cum extraction TG set, pressure : 25 kg/cm2, 380 Deg.c , extraction : 7 kg/cm2.
Steam turbine of 1 x 7.5 MW rated backpressure TG set, pressure : 32 kg/cm2, 400 Deg.c
Steam turbine of 1x 10 MW rated backpressure TG set, pressure : 42 bar, 410 Deg.c
Steam turbine of 1 x 12 MW rated condensing with controlled bleedings TG set, pressure : 62 /74 bar,470/485 Deg.c
Steam turbine of 1 x 15.75 MW rated backpressure Tg set, pressure : 58-69 bar, 440/475 Deg.c
Steam turbine of 1 x 13.2 MW rated backpressure Tg set, pressure : 58-69 bar, 450/475 Deg.c
Steam turbine of 1 x 2.5 MW rated backpressure TG set, pressure : 30 kg/cm2, 370 Deg.c
Steam turbine of 2 x 2 MW rated backpressure TG set, pressure : 21 kg/cm2, 340 Deg.c
Used power transformer, capacity : 15.8/ 21 MVA,Voltage : 132 kv/6.3 kv Available.
Turbine 1
Capacity
3500 KW
Year of Manu
1969
Made by
Siemens
Type
backpressure
Inlet pressure
40 bar
Temp
400 Deg.c
RPM
10000
Exhaust pressure
3 - 6 bar
Alternator
Make
Siemens
Capacity
4800 KVA
Hz
50
Speed
1500 rpm
Phases
3
Power Factor
0.8
Turbine 2
Capacity
2500 KW
Year of Manu
1967
Made by
TOSI
Type
backpressure
Inlet pressure
42 bar
Temp
420 Deg.c
Exhaust Pressure
6 bar
RPM
9000
Alternator
Make
Marelli
Capacity
3125 KVA
RPM
1500
Hz
50
Power Factor
0.8
Turbine 3
Capacity
250 KW
Made by
GMP
Year of construction
1995
Inlet steam pressure
48.5 kg/cm2
Steam temperature
445 Deg.C
Type
Backpressure
backpressure
2.5 kg/cm2 at 266 Deg.c
RPM
2970
Condition
Un-used, packed
Refurbishing Turbines : We Undertake Refurbishing of old turbines. We provide state of the art refurbishing solutions for your steam turbines. Please contact us.